11A 1kV 10,3x38mm 10kA 5AG AGU midget fuse Littelfuse 0FLU011.T *new*

  • 11A 1kV 10,3x38mm 10kA 5AG AGU midget fuse Littelfuse 0FLU011.T *new*
  • Manufacturer:
    Littelfuse
    Littelfuse
  • Model:
    Littelfuse 0FLU011.T FLU 11A *new*
  • Dimension:
    38 x 10decimal_point30 x 10decimal_point30 mm
  • Weight:
    8 g
  • Availability: 2pcs
  • Condition: New
  • Price Including VAT: 17,57€

  • Ex Tax: 14€
pcs


Make an offer

10x38mm midget fuse for applications that demand slightly more current and breaking capability. For example midget fuses can be found in following applications:

  • Multimeters
  • Some electrical devices
  • Industrial electrical installations

Fuses technical details:

  • Size class:
    • Midget fuse
    • 5AG
    • AG5
    • AGU
  • Speed class:
    • Fast acting
  • Nominal maximum operating voltage:
    • 1kVAC / 1kVDC
  • Nominal maximum current:
    • 11A
  • Breaking capacity:
    • 20kA
  • Blown fuse indicator:
    • There is no

Common information about the industrial fuse markings.
Industrial fuses among other fuses have various intended uses and because and as a result they have few different parameters, which can vary between fuses. Here is a list and explanation of the most important parameters according to the IEC 60269 standard:

  • Typical fuse speed markings:
    • Extremely fast acting:
      • aR:
        • Partial-range breaking capacity (short-circuit protection only) for the protection of Power Semiconductors.
      • gR:
        • Full-range breaking capacity (overload and short-circuit protection) for the protection of Power Semiconductors or rectifiers.
    • Fast acting:
      • gG:
        • Full-range breaking capacity (overload and shortcircuit protection) for general applications.
      • gL:
        • Same as gG (old marking practice).
      • gM:
        • Full-range breaking capacity (overload and shortcircuit protection) for the protection of motor circuits.
      • gPV:
        • Protection of solar photovoltaic arrays.
    • Slow acting:
      • aM:
        • Partial-range breaking capacity (short-circuit protection only) for the protection of motor circuits.
    • Less common markings:
      • gS:
        • Full-range breaking capacity (overload and short-circuit protection) for the protection of batteries & power semiconductors in drives.
      • gB:
        • Full-range breaking capacity (overload and shortcircuit protection) robust for mining application.
      • gTr:
        • Full-range breaking capacity (overload and shortcircuit protection) for protection of transformers.
      • gRL:
        • Full-range breaking capacity (overload and short-circuit protection) for the protection of Power Semiconductors, Line & Cable Protection.
      • gN:
        • Conductors sized to North American practice
  • Fuse breaking capacity: