11A 1kV 10,3x38mm 10kA 5AG AGU midget fuse Littelfuse 0FLU011.T *new*
- Manufacturer:
Littelfuse - Model:
Littelfuse 0FLU011.T FLU 11A *new* - Dimension:
38 x 10decimal_point30 x 10decimal_point30 mm - Weight:
8 g - Availability: 2pcs
- Condition: New
-
Price Including VAT: 17,57€
- Ex Tax: 14€
10x38mm midget fuse for applications that demand slightly more current and breaking capability. For example midget fuses can be found in following applications:
- Multimeters
- Some electrical devices
- Industrial electrical installations
Fuses technical details:
- Size class:
- Midget fuse
- 5AG
- AG5
- AGU
- Speed class:
- Fast acting
- Nominal maximum operating voltage:
- 1kVAC / 1kVDC
- Nominal maximum current:
- 11A
- Breaking capacity:
- 20kA
- Blown fuse indicator:
- There is no
Common information about the industrial fuse markings.
Industrial fuses among other fuses have various intended uses and because and as a result they have few different parameters, which can vary between fuses. Here is a list and explanation of the most important parameters according to the IEC 60269 standard:
- Typical fuse speed markings:
- Extremely fast acting:
- aR:
- Partial-range breaking capacity (short-circuit protection only) for the protection of Power Semiconductors.
- gR:
- Full-range breaking capacity (overload and short-circuit protection) for the protection of Power Semiconductors or rectifiers.
- aR:
- Fast acting:
- gG:
- Full-range breaking capacity (overload and shortcircuit protection) for general applications.
- gL:
- Same as gG (old marking practice).
- gM:
- Full-range breaking capacity (overload and shortcircuit protection) for the protection of motor circuits.
- gPV:
- Protection of solar photovoltaic arrays.
- gG:
- Slow acting:
- aM:
- Partial-range breaking capacity (short-circuit protection only) for the protection of motor circuits.
- aM:
- Less common markings:
- gS:
- Full-range breaking capacity (overload and short-circuit protection) for the protection of batteries & power semiconductors in drives.
- gB:
- Full-range breaking capacity (overload and shortcircuit protection) robust for mining application.
- gTr:
- Full-range breaking capacity (overload and shortcircuit protection) for protection of transformers.
- gRL:
- Full-range breaking capacity (overload and short-circuit protection) for the protection of Power Semiconductors, Line & Cable Protection.
- gN:
- Conductors sized to North American practice
- gS:
- Extremely fast acting:
- Fuse breaking capacity:
- Typically indicated in kA (kiloamperes, ie in thousands of amperes). This value means that the fuse is capable of break the xkA amount of current generated by short circuit/fault condition and as an outcome fuse will successfully extinguish the arc inside the fuse.
Tags: Littelfuse, FLU-series, midget fuse, FLU 11A, 11A, 1kV, tube, 10x38mm, fuse, tube fuse, cartridge fuse, 5AG, glass tube fuse, AGU, AG5, fuse for Fluke, multimeter fuse
Recently viewed
Price Inc. Tax: 17,57€ Price Ex. Tax: 14€
Availability: 2