Eaton Grouse-Hind series GHG 411 8100 R0004 cam switch 1x NO + 1x NC contacts, label 0 and 1, Ex II

  • Eaton Grouse-Hind series GHG 411 8100 R0004 cam switch 1x NO + 1x NC contacts, label 0 and 1, Ex II
    Eaton Grouse-Hind series GHG 411 8100 R0004 cam switch 1x NO + 1x NC contacts, label 0 and 1, Ex II Eaton Grouse-Hind series GHG 411 8100 R0004 cam switch 1x NO + 1x NC contacts, label 0 and 1, Ex II Eaton Grouse-Hind series GHG 411 8100 R0004 cam switch 1x NO + 1x NC contacts, label 0 and 1, Ex II
  • Manufacturer:
    Eaton
    Eaton
  • Model:
    Eaton Grouse-Hind series GHG4118100R0004
  • Dimension:
    85 x 85 x 108 mm
  • Weight:
    313 g
  • Availability: 1pcs
  • Condition: Used
  • Price Including VAT: 169.43€

  • Ex Tax: 135€
pcs


Make an offer

This robust control switch is explosion-proof, which means it has ATEX specification and it can be used in hazardous, explosion prone industrial environments.

Switch technical details:

  • Max rated operating voltage (Ui):
    • 690VAC
  • Utilization category (Unmarked classes = Manufacturer has not provided information or we just do not have that particular information):
    • AC-1, (Ith, Iu) Non-inductive or slightly inductive loads, example: resistive furnaces, heaters
      • 16A / 690VAC
    • AC-2, Slip-ring motors: starting, switching off
    • AC-3, Squirrel-cage motors: starting, switches off spinning motors
    • AC-4, Squirrel-cage motors: starting, plugging, inching
    • AC-5a, Switching of discharge lamps
    • AC-5b, Switching of incandescent lamps
    • AC-6a, Switching of transformers
    • AC-6b, Switching of capacitor banks
    • AC-7a, Slightly inductive loads in household appliances: examples: mixers, blenders
    • AC-7b, Motor-loads for household appliances: examples: fans, central vacuum
    • AC-8a, Hermetic refrigerant compressor motor control with manual resetting overloads
    • AC-8b, Hermetic refrigerant compressor motor control with automatic resetting overloads
    • AC-12, Control of resistive loads and solid state loads with opto-coupler isolation
    • AC-13, Control of solid state loads with transformer isolation
    • AC-14, Control of small electromagnetic loads (<72VA)
    • AC-15, Control of electromagnetic loads (>72VA)
      • Ex41:
        • 6A / 250VAC
        • 4A / 500VAC
      • Ex23:
        • 6A / 230VAC
        • 4A / 500VAC
    • AC-20, Connecting and disconnecting under no-load conditions
    • AC-21A, (Ie) Frequent switching of resistive loads, including moderate overloads
    • AC-21B, (Ie) Occasional switching of resistive loads, including moderate overloads
    • AC-22A, Frequent switching of mixed resistive and inductive loads, including moderate overloads
    • AC-22B, Occasional switching of mixed resistive and inductive loads, including moderate overloads
    • AC-23A, Frequent switching of motor loads or other highly inductive loads
    • AC-23B, Occasional switching of motor loads or other highly inductive loads
    • DC-1, Non Inductive or slightly inductive loads, resistance furnaces, heaters
    • DC-3, Shunt-motors, starting, plugging(1), inching(2), dynamic braking of motors
    • DC-5, Series-motors, starting, plugging(1), inching(2), dynamic braking of motors
    • DC-6, Switching of incandescent lamps
    • DC-12, Control of resistive loads and solid state loads with opto-coupler isolation
    • DC-13, Control of electromagnetics
      • Ex41:
        • 6A / 24VDC
        • 1A / 220VDC
      • Ex23:
        • 2A / 24VDC
        • 0,5A / 230VDC
    • DC-14, Control of electromagnetic loads when having variable resistors in the circuit
    • DC-20A, Frequent connecting and disconnecting under no-load conditions
    • DC-20B, Occasional connecting and disconnecting under no-load conditions
    • DC-21A, Frequent switching of resistive loads, including moderate overloads
    • DC-21B, Occasional switching of resistive loads, including moderate overloads
    • DC-22A, Frequent switching of mixed resistive and inductive loads, including moderate overloads (i.e. shunt motors)
    • DC-22B, Occasional switching of mixed resistive and inductive loads, including moderate overloads (i.e. shunt motors)
    • DC-23A, Frequent switching of highly inductive loads (i.e. series motors)
    • DC-23B, Occasional switching of highly inductive loads (i.e. series motors)
  • Connecting terminals:
    • 2x 2,5 mm2
  • Cable feed-through:
    • 1x M25
  • IP-rating:
    • IP66
  • EC-type examination certificate:
    • PTB 00 ATEX 3117
  • IECEx certificate of conformity:
    • IECEx BKI 04.0003
  • ATEX markings:
    • Ex II 2 G Ex ed ib m IIC T6
    • Ex II 2 D Ex tD A21 IP66 T80 °C
    • Ex e II T6, Ex e ib IIC T6, Ex ed IIC T6 or Ex ed ib IIC T6

Download Eaton Grouse-Hinds series Ex-control stations technical datasheet

Switches electrical
Locking option Yes
Max current 25A
Max voltage 690V

Write a review

Please login or register to review

Tags: Eaton, GHG- series, 411 81-series, GHG411-series, control switch 1x NO + 1x NC, control switch, control switch, safety, switch, safety switch, 16A, cam switch, ATEX, Ex

Recently viewed


Price Inc. Tax: 169.43€ Price Ex. Tax: 135€

Availability: 1