ABB OT16ET3 general purpose disconnect switch, 3-Pole, 16A, 600VAC 10HP with handle
- Manufacturer:
Baco - Model:
ABB OT16ET3 general purpose disconnect switch, 3P, 16A, 600VAC - Dimension:
90decimal_point10 x 54 x 48decimal_point20 mm - Weight:
127 g - Availability: 1pcs
- Condition: Used
-
Price Including VAT: 17,57€
- Ex Tax: 14€
This switch is designed for general-purpose use, such as disconnecting power to motors and other equipment. The 3-pole design is suitable for three-phase systems, and the 16-amp current rating supports loads up to 10 horsepower at 600 volts. The handle makes it easy and safe to operate and disconnect the device.
Applications:
- As main switch for electrical cabinets
- As main switch or emergency stop switch for machinery.
Disconnect switch technical details:
- Max rated operating voltage (Ui):
- 690V
- Max rated impulse withstand voltage:
- 8kV
- Rated max motor power (information has been pulled from the contactor, the product catalogues states different information):
- 200VAC
- 2HP 3~
- 206VAC
- 2HP 3~
- 240VAC
- 2HP 3~
- 480VAC
- 7,5HP 3~
- 600VAC:
- 7,5HP 3~
- 200VAC
- Utilization category (Unmarked classes = Manufacturer has not provided information or we just do not have that particular information):
- AC-1, (Ith, Iu) Non-inductive or slightly inductive loads, example: resistive furnaces, heaters
- 25A / 690VAC
- AC-2, Slip-ring motors: starting, switching off
- AC-3, Squirrel-cage motors: starting, switches off spinning motors
- AC-4, Squirrel-cage motors: starting, plugging, inching
- AC-5a, Switching of discharge lamps
- AC-5b, Switching of incandescent lamps
- AC-6a, Switching of transformers
- AC-6b, Switching of capacitor banks
- AC-7a, Slightly inductive loads in household appliances: examples: mixers, blenders
- AC-7b, Motor-loads for household appliances: examples: fans, central vacuum
- AC-8a, Hermetic refrigerant compressor motor control with manual resetting overloads
- AC-8b, Hermetic refrigerant compressor motor control with automatic resetting overloads
- AC-12, Control of resistive loads and solid state loads with opto-coupler isolation
- AC-13, Control of solid state loads with transformer isolation
- AC-14, Control of small electromagnetic loads (<72VA)
- AC-15, Control of electromagnetic loads (>72VA)
- AC-20, Connecting and disconnecting under no-load conditions
- AC-21A, (Ie) Frequent switching of resistive loads, including moderate overloads
- 16A / 690VAC
- AC-21B, (Ie) Occasional switching of resistive loads, including moderate overloads
- AC-22A, Frequent switching of mixed resistive and inductive loads, including moderate overloads
- 16A / 380...690VAC
- AC-22B, Occasional switching of mixed resistive and inductive loads, including moderate overloads
- AC-23A, Frequent switching of motor loads or other highly inductive loads
- 3kW / 220...240VAC
- 7,5kW / 400VAC
- 7,5kW /415VAC
- 7,5kW /690VAC
- AC-23B, Occasional switching of motor loads or other highly inductive loads
- DC-1, Non Inductive or slightly inductive loads, resistance furnaces, heaters
- DC-3, Shunt-motors, starting, plugging(1), inching(2), dynamic braking of motors
- DC-5, Series-motors, starting, plugging(1), inching(2), dynamic braking of motors
- DC-6, Switching of incandescent lamps
- DC-12, Control of resistive loads and solid state loads with opto-coupler isolation
- DC-13, Control of electromagnetics
- DC-14, Control of electromagnetic loads when having variable resistors in the circuit
- DC-20A, Frequent connecting and disconnecting under no-load conditions
- DC-20B, Occasional connecting and disconnecting under no-load conditions
- DC-21A, Frequent switching of resistive loads, including moderate overloads
- 32A (depends on the operating voltage and number of contacts in series)
- DC-21B, Occasional switching of resistive loads, including moderate overloads
- 32A (depends on the operating voltage and number of contacts in series)
- DC-22A, Frequent switching of mixed resistive and inductive loads, including moderate overloads (i.e. shunt motors)
- 32A (depends on the operating voltage and number of contacts in series)
- DC-22B, Occasional switching of mixed resistive and inductive loads, including moderate overloads (i.e. shunt motors)
- 32A (depends on the operating voltage and number of contacts in series)
- DC-23A, Frequent switching of highly inductive loads (i.e. series motors)
- 30A (depends on the operating voltage and number of contacts in series)
- DC-23B, Occasional switching of highly inductive loads (i.e. series motors)
- 30A (depends on the operating voltage and number of contacts in series)
- AC-1, (Ith, Iu) Non-inductive or slightly inductive loads, example: resistive furnaces, heaters
- Breaking capacity:
- 220A
- Max compatible lead size:
- 0,75...10 mm² (AWG 18-7) single-core or stranded copper wire
- IP-rating:
- IP20
- Expandability:
- For example auxiliary contact block module can be connected into switch
- Number of contacts:
- 3x NO (normally open)
Download ABB OT16ET3 general purpose disconnect switch technical datasheet
Switches electrical | |
Locking option | Yes |
Max current | 25A |
Max voltage | 690V |
Tags: ABB, OT16ET3, general purpose disconnect switch, disconnect switch, 3-Pole, 16A, 600VAC, 10HP