10A 2-phase C-type automatic fuse / miniature circuit breaker Schneider Electric iC60N Acti9 A9F04210 C10A 240VAC / 440VAC *new*

  • 10A 2-phase C-type automatic fuse / miniature circuit breaker Schneider Electric iC60N Acti9 A9F04210 C10A 240VAC / 440VAC *new*
  • Manufacturer:
    Schneider Electric
    Schneider Electric
  • Model:
    Schneider Electric iC60N Acti9 A9F74210 C10A *new*
  • Dimension:
    90 x 36 x 75 mm
  • Weight:
    222 g
  • Availability: 1pcs
  • Condition: New
  • Price Including VAT: 25,10€

  • Ex Tax: 20€
pcs


Make an offer

An overcurrent circuit breaker is a component of an electrical installation whose function is to break the continuity of a circuit when the current exceeds the safe value for that circuit. The circuit breaker is designed to control and protect against the effects of overloads and short circuits of consumer circuits of the installation, as well as household electrical appliances. It is designed for repeated use.

Multipurpose automatic fuse for DIN rail mounting. Automatic circuit breaker can be used in various application such as:

  • Electrical cabinet
  • Electrical device
  • Industrial electrical installations
  • Household electrical installation
  • Protecting electrical motor (Large motors require slow fuses such as D-class or even slower)

Automatic circuit breaker technical details:

  • Product ID:
    • Acti9
  • Product type:
    • Miniature circuit breaker
  • Trip unit technology:
    • Thermal-magnetic
  • Maximum rated operating voltage:
    • 440VAC
  • Maximum rated current:
    • 10A
  • Trip curve:
    • C
  • Maximum short-circuit breaking capacity:
    • 36 kA Icu / 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2
    • 20 kA Icu / 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2
    • 10 kA Icu / 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2
    • 6 kA Icu / 440 V AC 50/60 Hz conforming to EN/IEC 60947-2
    • 10 kA Icu / <= 180 V DC conforming to EN/IEC 60947-2
    • 6000 A Icn / 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
  • Rated service breaking capacity Ics:
    • 27 kA 75 % x Icu / 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2
    • 15 kA 75 % x Icu / 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2
    • 7.5 kA 75 % x Icu / 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2
    • 4.5 kA 75 % x Icu / 440 V AC 50/60 Hz conforming to EN/IEC 60947-2
    • 10 kA 100 % x Icu / <= 180 V DC conforming to EN/IEC 60947-2
  • Rated insulation voltage (Ui):
    • 500VAC 50/60Hz conforming to EN/IEC 60947-2
  • Rated impulse withstand voltage (Uimp):
    • 6kV conforming to EN/IEC 60947-2
  • Rated frequency:  
    • 50/60Hz
  • Contact position indicator:
    • Yes
  • Connection terminals:
    • Single terminal (top or bottom) 1…25mm² rigid copper conductor
    • Single terminal (top or bottom) 1…16mm² flexible copper conductor/copper conductor with ferrule
  • Operating temperature:
    • -35...+70°C
  • Number of poles:
    • 3P
  • IP-class:
    • IP20
  • Mechanical durability:
    • 20000 cycles
  • Electrical durability:
    • 10000 cycles
  • Installation method:
    • 35mm DIN-rail
  • Pollution degree:
    • 3 conforming to ENIEC 60947-2
  • Overvoltage category:
    • IV
  • Tropicalisation:
    • 2 conforming to IEC 60068-1
  • Utilisation category:
    • Category A conforming to EN/IEC 60947-2
  • Suitability for isolation:
    • Yes conforming to EN/IEC 60898-1
    • Yes conforming to EN/IEC 60947-2
  • Standards: 
    • EN/IEC 60898-1
    • EN/IEC 60947-2

Download Schneider Electric iC60N Acti9 A9F04210 miniature circuit breaker technical datasheet