Miflex MKSP-I18 I18UV665I-A 65µF/450VAC 60x152mm motor run capacitor with faston terminals *new*

  • Miflex MKSP-I18 I18UV665I-A 65µF/450VAC 60x152mm motor run capacitor with faston terminals *new*
    Miflex MKSP-I18 I18UV665I-A 65µF/450VAC 60x152mm motor run capacitor with faston terminals *new* Miflex MKSP-I18 I18UV665I-A 65µF/450VAC 60x152mm motor run capacitor with faston terminals *new*
  • Manufacturer:
    Miflex
    Miflex
  • Model:
    Miflex MKSP-I18 I18UV665I-A *new*
  • Dimension:
    152 x 60 x 60 mm
  • Weight:
    383 g
  • Availability: 1pcs
  • Condition: New
  • Price Including VAT: 27.28€

  • Ex Tax: 22€
pcs


Make an offer

A motor capacitor, such as a start capacitor or run capacitor is an electrical capacitor that alters the current to one or more windings of a single phase AC induction motor to create a rotating magnetic field. Commonly motor capacitors are categorized as a motor run capacitors and motor start capacitors. Motor run capacitors are intended for continuous operation and as the name suggest motor start capacitor helps motor to start up. Ie some motors do only have one motor run capacitor and some do have motor run capacitor and motor start capacitor (separately or as a combination capacitor). The units of capacitance are labeled in microfarads (µF or uF or "mfd" or "MFD", which still refers to "micro", not "milli" or "mega").

Typical motor capacitor fault symptoms:

  • Capacitor is swollen/cracked/blown/leaked
  • Motor is weak
  • The motor makes an exceptionally high vibration / buzz (may also indicate a bearing failure, for example)
  • Motor does not start spinning without help (although spins freely by itself when spun manually, ie nothing caches to anything internally)
  • The charge capacitance µF value of the motor capacitor differs from the value stated value by more than the given tolerance when measured with a LCR meter or a multimeter capable measuring  capacitors
  • Motor smells burned (could also be a motor failure)
  • Motor blows a fuse (could also be a motor failure)

Capacitor technical details:

  • Capacitance:
    • 65µF +/-5%
  • Intended use:
    • Electric motor run capacitor
  • Max operating voltage:
    • 450VAC 50/60Hz
      • 400VAC 10000h/class B
      • 450VAC 3000h/class C
  • Climatic conditions according to IEC 60068 standard:
    • 40/085/21 (-40°C...85°C for 21 days)
    • Lower category temperature / Upper category temperature / Number of days, the duration of test (damp heat, steady state) at a relative humidity of 93% +2...-3% and an ambient temperature of 40°C
  • Mounting:
    • 12mm M12 screw
  • Overall diameter:
    • 60mm
  • Overall length (including connectors):
    • 152mm
  • Connectors:
    • 2x dual 6,25x0,8mm spade connectors (faston terminals)

Below is an indicative table of capacitor size classes for motors. Primarily check/follow the motor manufacturer's instructions/values. If you need to round the value to a suitable capacitor then we recommend rounding up to the next closest suitable, as long as you do not have to deviate more than 5% from that correct value. The aged capacitors we have encounter lose their charge capacity with age (µF value decreases) therefore we recommend rounding up.

Single phase motor run capacitors µF value
Motor power in kilowatts 0,075kW 0,18kW 0,37kW 0,55kW 0,75kW 0,92kW 1,1kW 1,5kW
Motor power in horsepowers 0,1hp 0,25hp 0,5hp 0,75hp 1hp 1,25hp 1,5hp 2hp
3000rpm/50Hz 2-pole 6,3µF 10µF 16µF 20µF 25µF 30µF 32µF 40µF
1500rpm/50Hz 4-pole 6,3µF 12,5µF 16µF 20µF 25µF 28µF 32µF 40µF
1000rpm/50Hz 6-pole   10µF 20µF 25µF 25µF 30µF 36µF 50µF
Three phase motor run capacitor µF value when used with single phase (Steinmetz circuit)
Motor power in kilowatts 0,18kW 0,37kW 0,55kW 0,75kW 0,92kW 1,1kW 1,5kW
Motor power in horse powers 0,25hp 0,5hp 0,75hp 1hp 1,25hp 1,5hp 2hp
Capacitor µF value upon full motor load 12,5µF 25µF 38µF 50µF 60µF 75µF 100µF
Motor start capacitor µF value (Motor run capacitor can act as a starting capacitor, but not the other way around!)
Motor power in kilowatts 0,075kW 0,18kW 0,37kW 0,55kW 0,75kW 1,1kW 1,5kW
Motor power in horse powers 0,1hp 0,25hp 0,5hp 0,75hp 1hp 1,5hp 2hp
Operating voltage 220VAC 20µF 50µF 100µF 150µF 200µF 300µF  
Operating voltage 280VAC 10µF 25µF 50µF 80µF 100µF 150µF 200µF

Download Miflex MKSP-I18 series motor run capacitor technical datasheet

Download general info about AC motor capacitors and how to size and calculate motor capacitor by Kemet

Write a review

Please login or register to review

Tags: motor capacitor, 400VAC, 450VAC, capacitor, 65µF, motor cap, 65uF, Miflex, cap, MKSP-series

Recently viewed


Price Inc. Tax: 27.28€ Price Ex. Tax: 22€

Availability: 1